Level regulation for infinity pool.
IP55 - IK07 protection.
Supply voltage 230 V.
Solenoid valve control voltage 24 V
Max. power. 10 VA.
Probes and solenoid valve optional (depending on pack)
Technical diagram buffer tank level regulator box
REGUL 1 FJ
3 probes / 1 function:
1. pump* and filling safety
a: reference probe
b: pump operation prohibited + solenoid valve opening
c: pump operation authorized + solenoid valve closed
REGUL 2
5 probes / 2 functions
1. pump safety
2. filling
a: reference probe
b: pump operation prohibited
c: pump operation authorization
d: solenoid valve opening|| |1374
e : fermeture électrovanne
REGUL 2 FJ
5 probes / 2 functions
1. pump and filling safety
2. high level pump restart
a: reference probe
b: pump operation prohibited + solenoid valve opening
c: pump operation authorized + solenoid valve closed
d*: stop forced pump on function
e*: start “forced pump on” function
*to avoid losing water in case of many bathers| ||1398
PRÉCONISÉ DANS BAC TAMPON (H. inf. 80cm)
REGUL 3
5 probes / 3 functions
1. pump safety
2. filling
3. high level pump restart
a: reference probe
b: pump operation prohibited
c: pump operation authorization + solenoid valve opening
d: prohibition of pump operation + solenoid valve closure
e: start of “pump forced start” function
RECOMMENDED IN BUFFER BIN (lower H. 80cm)
REGUL 37 probes / 3 functions
1. pump safety
2. filling
3. high level pump restart
a: reference probe
b: pump operation prohibited
c: pump operation authorization
d: opening solenoid valve
e: solenoid valve closing
f: stop “forced pump start” function
g: start “forced pump start” function