level regulationREGUL BAC PON .
These regulation boxes allowmaintaining the water level in the basin andensuring constant overflow.The probes (3, 5 or 7 depending on model)placed in the buffer tank, will detectthe water level and allow theregulator to adjust it in completeautonomy. By ensuring a certain water level, theboxes allow the pump to bepreserved and prevent its depriming.



Sonde et électrovanne en option

Level regulation for infinity pool.

Logo_Fabrique_en_France

Coffret electrique regulation niveaux piscine a debordement


IP55 - IK07 protection.
Supply voltage 230 V.
Solenoid valve control voltage 24 V
Max. power. 10 VA.
Probes and solenoid valve optional (depending on pack)




Technical diagram buffer tank level regulator box

schema coffret piscine bac tampon 3 sondes schema coffret piscine bac tampon 5 sondes schema coffret piscine bac tampon 7 sondes


REGUL 1 FJ

3 probes / 1 function:

1. pump* and filling safety

a: reference probe
b: pump operation prohibited + solenoid valve opening
c: pump operation authorized + solenoid valve closed


REGUL 2

5 probes / 2 functions

1. pump safety
2. filling

a: reference probe
b: pump operation prohibited
c: pump operation authorization
d: solenoid valve opening|| |1374
e : fermeture électrovanne


REGUL 2 FJ

5 probes / 2 functions

1. pump and filling safety
2. high level pump restart

a: reference probe
b: pump operation prohibited + solenoid valve opening
c: pump operation authorized + solenoid valve closed
d*: ​​stop forced pump on function
e*: start “forced pump on” function
*to avoid losing water in case of many bathers| ||1398
PRÉCONISÉ DANS BAC TAMPON (H. inf. 80cm)

REGUL 3

5 probes / 3 functions

1. pump safety
2. filling

3. high level pump restart
a: reference probe
b: pump operation prohibited
c: pump operation authorization + solenoid valve opening
d: prohibition of pump operation + solenoid valve closure
e: start of “pump forced start” function
RECOMMENDED IN BUFFER BIN (lower H. 80cm)


REGUL 3

7 probes / 3 functions

1. pump safety
2. filling
3. high level pump restart

a: reference probe
b: pump operation prohibited
c: pump operation authorization
d: opening solenoid valve
e: solenoid valve closing
f: stop “forced pump start” function
g: start “forced pump start” function